Carbon Molecular Sieves

Carbon Molecular Sieves

Description

CMS is used to separate oxygen from nitrogen for high-purity nitrogen generation through PSA technology.

Application

  1. Nitrogen production for chemical, food, metal, and electronics industries.

  2. Biogas upgrading, air separation, and hydrogen purification.

Precaution

  • The product as desiccant cannot be exposed in the open air and should be stored in dry condition with air-proof package.

Variants Available

There are five variants available.

DT-CMS

CMS Data Table

Testing Temperature: ≤20°C

Adsorption Time: 2*60s

Adsorption Pressure: 0.75-0.8MPa

Bulk Density: 620-700g/L

Variant Type Size (mm) Crush Strength (N/Pc) Purity (%) Productivity (Nm³/h.t) Air / N₂
CMS2N 1.2 ≥50 98 300 2.3
99 260 2.4
99.5 220 2.6
99.9 145 3.7
99.99 100 4.8
99.999 55 6.8
CMS4N 1.2 ≥50 98 320 2.2
99 280 2.3
99.5 240 2.5
99.9 160 3.5
99.99 110 4.6
99.999 65 6.6
CMS6N 1.2 ≥50 99.5 260 2.4
99.9 175 3.4
99.99 120 4.6
99.999 75 6.5
CMS8N 1.0 ≥40 99.5 280 2.3
99.9 190 3.4
99.99 135 4.5
99.999 90 6.4
CMS3PN 1.2 ≥35 99.5 330 2.8
99.9 250 3.3
99.99 165 4.0
99.999 95 6.4